Z-Secure attachment system
Z-Secure is a patented metal anchor made for commercial doors. It ties the filmed glass to the door itself, not just to the removable strip around it.
We are an authorized Z-Secure dealer in Utah.
On a window, security film is anchored with a structural silicone bead because the glass sits in a deep, fixed frame — the bead has something immovable to bond to. Commercial doors are built differently: the glass sits in a removable glazing stop, often with a compression gasket, and the stop is designed to come out so the glass can be replaced.
Run a silicone bead between the filmed glass and that stop and you have bonded the film to a part that was engineered to be removable. Break the glass and push, and the filmed pane and its stop leave the door together. The film did its job perfectly. There is still a hole.
This is not a theoretical objection. It is the specific failure that led to the system being invented — see why it exists.
How it works
Z-Secure is a metal piece made to fit each door. In cross-section it has two 90° bends, a Z shape.
Close-up, looking down on the door edge
anchorfilmglazing stopframe
One end grips the door frame, it runs across the glazing stop, and the other end rests on the face of the filmed glass. That ties the glass to the door. Because glazing stops differ from door to door, each one is made to measure.
It works on glass, and on acrylic and polycarbonate glazing such as Lexan.
Gallery
The commonest objection to anchoring is that it will look like bolted-on hardware. It is a finished metal edge detail matched to the frame color, and on most doors it reads as part of the frame. Judge for yourself.
Where a building could be identified, we have blurred it out — security work does not get published with a name or address attached.
Specifications
ZSECURE® and the ZSECURE seal are trademarks of Secure Glass Pros, Inc. Logos and product documentation are used with the manufacturer’s permission. US Patent Nos. 9,938,763 · 10,400,503 B2 · 10,837,223 B2.
Z-Secure is an anchoring system, not a film. It is specified alongside a security film — we quote both, name both, and attach both sets of documentation.
Testing & documents
What exists for Z-Secure, so an architect or facility manager can cite it.
9,938,763, 10,400,503 B2 and 10,837,223 B2. Public record at the USPTO.
A published specification section exists for the system, so an architect can include it in a submittal package without writing it from scratch.
A 2022 technical data sheet and an independent test report are available from the manufacturer on request. We send them with any quote.
Independent testing by Intertek on door glass, 34 by 86 inches, 8 mil clear film, 48 inch drop. The pass criterion: no opening a 3 inch sphere can freely pass with 4 pounds of force.
| No anchoring | Glass came out of the frame on the first impact. |
|---|---|
| Film with silicone to the glass stops | Passed the first impact; glass came out of the frame on the second. |
| Z-Secure anchoring with adhesion promoter | Glass cracked and stayed in the frame through three impacts, with no opening. |
Intertek report Q9291.01-801-44-R4, tested February 2024.
One specimen, 1/4 inch glass, 8 mil clear film, Z-Secure fitted. After 9 weeks of temperature cycling from 180°F to 0°F, there was no breakage or deformation. A uniform load of 3,600 Pa in each direction (75 psf), per ASTM E330, caused less than 0.1 mm (0.01 inch) of deformation. In six drop impacts from 48 inches, the glass cracked on the first and stayed attached; on impacts 2 to 4 the anchor bent without separating; impacts 5 and 6 caused no change.
Intertek report R5383.01-801-44-R2, tested September 2024.
Retrofits
If your doors were filmed and anchored with a silicone bead to the glazing stop, the anchor can be added without replacing the film. That matters, because the usual alternative — strip the film, re-anchor, re-film — costs more and takes the doors out of service for longer.
Worth checking if: the film was installed by someone else, you inherited the building, or the installation predates whoever now manages it. We will look at what is there and tell you honestly whether it needs anything.
For architects and specifiers
| Document | What it covers |
|---|---|
| CSI 08 88 53 section | Security Glazing Anchoring System — the specification section for the anchor itself. |
| Technical data sheet | Profile geometry, frame bite, finishes, glazing types and fabrication tolerances. |
| Independent test report | Issued by the manufacturer on request; we pass it through unedited. |
| Film specification | The security film specified alongside it — manufacturer, product, thickness and its own test data. Which standard means what. |
| Finish schedule | Anodized and painted options matched to the door frames on your project. |
If a scope has already been written specifying a silicone bead on door glazing, we will say so and explain why — before the bid, not after the install.
Questions
No. It is the anchor that holds filmed glazing in a door. It is always specified alongside a security film — the film holds the broken glass together, the anchor keeps that assembly in the door. Neither does the other’s job.
Yes, if you look. It is a finished metal edge detail around the glazing, available in anodized and painted finishes matched to common frame colors, so on most doors it reads as part of the door rather than as added hardware. It is considerably more discreet than rubberized glazing tape, which is the usual visible alternative.
Because the issue is not the quantity or quality of the sealant — it is what the sealant is bonded to. On a commercial door that is a glazing stop designed to be removed. A stronger bond to a removable part still leaves you with a removable part.
It depends on the door. The system is fabricated to the specific door style, and some configurations suit it better than others. This is exactly what the on-site assessment settles — we measure the doors before quoting anything.
Usually not. If the glazing already carries sound security film, the anchor can generally be added to the existing installation. See retrofits.
Z-Secure is sold through a selected dealer network. Shade N Shield is an authorized Z-Secure dealer in Utah, and we install it across Utah, Salt Lake, Davis, Wasatch and Summit counties.
Free on-site assessment. We measure the glazing stops and tell you what the doors actually need.